• chandan@oxenro.com
    Email us
  • +91 98250 83672Call us

Product Detail

Membrane Amfor 2540/4021/4040

Type Model Performance Structure Parameter
Stabilized Salt Rejection% Permeate flow rate gpd (m3/d)

Effective membrane area /ft2

Flow Path Dia / mil

Inner pipe Dia/mm
Model TW30XLE-2540 99.0 850(3.21) 28(2.6) 28  
TW30XLE-4021 99.0 1000(3.78) 36(3.3)   19
TW30XLE-4040 99.0 2340 (8.85) 87 31 19.0
Testing conditions Testing Pressure 225psi(1.55MPa)
Temperature of testing 25ºC
Testing Concentration (NaCl) 2000 mg/L
pH Value of testing 7.5

Applied Pressure psig (bar)

225 (15.5)
Recovery of single membrane element 20%
Operation limits and conditions Max. Working Pressure 600 psi (4.14 MPa)
Max. Feed water Flow 6 gpm (1.4 m3/hr) (2540)
16 gpm (3.6 m3/h) (4021)
Max inflow temperature 45ºC
Max flow SDI15 5
Residual Chlorine Concentration of feed water <0.1 mg/L
pH range of Feed water during Continuous Operation 2~11
pH range of feed water during chemical cleaning 1~13
Max, Pressure Drop of Single membrane element 13 psig (0.9 bar)